Series 9000E Bar Code Scanner/Decoder
6-2
PROGRAMMING
Host commands are accessed via the host port of the Series 9000E Bar
Code Scanner/Decoder . A communications package such as Telix,
Procomm, SSDL or LCDOS can be used.
Type CTRL-R and the following prompt will appear ">:"
At this point the user has entered the Host Commands mode.
All Host Commands must be capitalized. Other text may be
upper or lower case.
END or EXIT will exit the Host Commands mode.
Control characters can be entered into text fields by bracketing the
command. Example: HSOM <STX> ENTER
The characters entered on the host port will not be echoed to the
terminal screen.
Host Command Prompt is defaulted as <CR><LF>>: . This prompt is
configurable by entering HCP plus the text. Example: HCP <STX>.