Product Reference Guide 2-7
Figure 2-2. Vertical Clearance
Ventilation and Spacing
The scanning-scales perimeter housing has been designed to provide ade-
quate space for convective cooling and unrestricted movement of the
weighing apparatus. Figure 2-3 shows the debris chutes and ventilation
slots. The checkstand design must allow:
The ambient air temperature inside the checkstand adjacent to
the scanner must not exceed 104°F (40°C).
A source of air that provides adequate cooling by convective air
flow.
DO NOT
Obstruct
Scan Zone
DO NOT
Obstruct
L-Platter
Removal
Allow a minimum
clearance of
1.5" (3.8cm)
(Enclosure)
(Keyboard Mount)
NOTE
DO NOT place the scanner in a close-fitting, fully enclosed checkstand. Pro-
vide a MINIMUM of 16 square inches (103.2 square centimeters) of air intake
from below the installation for sufficient convective cooling.