Vue de la page 418
Product Reference Guide F-3
UPC-A with 5-Digit Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be
correct.
Prefix must be an ASCII character 'A' - total length including
prefix must be 18.
Example: 'A06099201118712345'.
UPC-A with Code 128 Supplemental
Number system must be included in label data.
Check digit must be included in label data and is assumed to be
correct.
Supplemental data is appended to base label.
Prefix must be an ASCII character 'A' - total length including
prefix must be greater or equal to 19 Code 128 Supplemental
codes are variable length having a minimum of 2 data characters).
Characters immediately following base label must be of the form
'8100', '8101' or '8102'.
Example: 'A0609920111878100000951'.
UPC-E
Number system must be included in label data.
Check digit must be included in label data and is assumed to be
correct.
Prefix must be an ASCII character 'E' - total length including pre-
fix must be 9.
Example: 'E09988750'.