NOTE
If the scale fails any of these tests, go to the topic
Scale Error
Reporting in Section 4, Problem Isolation, of this manual.
6-14 Magellan
TM
8500Xt Scanner
Increasing-Load Test (Phase 1)
This test checks scale operation for increasing loads from 0.050 kg and 3
kg.
1. Check that the display reads 0.000 kg when at r
est with nothing
on the weighing surface. (The Zero Status LED is on steady).
2. Place a 50 gram weight on the center of th
e weighing surface and
check that the Remote Display reads 50 grams.
3. Place an additional 100 grams on the center of the weighing sur-
face (.0300 kg. total) and check that the Remote Display reads
1
50 grams.
4. Place an additional 100 grams on the center of the weighing sur-
face and check that the Remote Display reads 250 grams.
5. Place an additional 50 grams on the center of the weighing sur-
face and check that the display reads 300 grams.
6. Place an additional 50 grams on the center of the weighing sur-
face and check that the display reads 350 grams.
7. Place an additional 50 grams on the center of the weighing sur-
face and check that the display reads 400 grams.
8. Place an additional 100 grams on the center of the weighing sur-
face and check that the display reads 500 grams.
9. Increase the weight on the center of the weighing surface to 2.5
kg
and check that the display reads between 2.998 and 3.002 kg.
10. Remove the weights and verify that the display reads 0.000 kg.
Y
ou have completed the Increasing-Load Test (Phase 1).