7-140 Magellan
TM
8500Xt Scanner
UPC-A Label ID
This feature specifies a UPC-A label ID to be added to barcode data.
NOTE
The programming feature, RS-232 Label ID Control, designates whether
the Label ID is transmitted as a prefix or suffix or if Label ID is disabled.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET UPC-A LABEL ID below. You’ll need to
cover any unused barcodes on this and the facing page to ensure
the scanner
reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired Label ID characters; entered as two hex
pairs. A table
containing the ASCII Character Set and their corre-
sponding Hex Values is available in the inside back cover of this
manual. ASCII parameters must be input b
y scanning a pair of
hexadecimal digits for each character. Thus, to set a two-character
value of AB, barcodes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’
must be scanned. The selectable range for this option is any hex
value from 00 to FF.
4. Complete the programming seque
nce by scanning the SWITCH
barcode.
SET UPC-A LABEL ID