7-250 Magellan
TM
8500Xt Scanner
Codabar Length 2
If Codabar Length Control is set to Fixed-Length decoding, this feature
specifies Codabar second fixed length. If Codabar Length Control is set to
Variable-Length decoding, this feature specifies the maximum label
length.
NOTE
When in Fixed Length mode, if Length 2 is set
to the value of 00 (zero),
then only Length 1 will apply.
To set this feature:
1. Scan the SWITCH barcode.
2. Scan the barcode, SET CODABAR LENGTH 2 below. You’ll
need to cover any unused barcodes on this and the facing page to
en
sure that the scanner reads only the barcode you intend to scan.
3. Scan the appropriate digits from the keypad in
Appendix C that
represent the desired label length. The selectable range for this
option is 00, or 03 to
50. Pad all single digit numbers with a lead-
ing zero to yield a two-digit entry (03-50).
4. Complete the programming seque
nce by scanning the SWITCH
barcode.
SET CODABAR LENGTH 2